Basic Serial Command Specifications
23/24
7.4. Input Mode Read Command
Get the selected Input No.
Response
%1
”1” = Computer 1 is selected
”2” = Computer 2 is selected
“3” = Video is selected
7.5. Lamp Time Read Command
Detail
Get the total lamp running hours (Not actual lamp used hour, but Eco mode
corresponding value).
Response
%1
Shows the time period with 5 digits numbers.
Example: “00410”[CR] ・・・・shows 410 hours
7.6. Setting Read Command
Get screen setting status such as Ceiling / Rear.
Response
%1
“11”[CR] = Normal Screen Setting
“10”[CR] = Picture is top/bottom reversed.
(Status: Rear&Ceiling ON)
“01”[CR] = Picture is left/right reversed. (Status: Rear ON)
“00”[CR] = Picture is top/bottom and left/right reversed.
(Status: Ceiling ON)
7.7. Temp Read Command
Detail
Get the temperature data inside the projector.
With some temperature sensors installed in the projector, it is possible to get all
the temperature at once.
Response
%1
%2
%3
%1=Temperature of sensor 1
%2=Temperature of sensor 2
%3=Temperature of sensor 3
Temperature data is shown as “00.0”.
When the temperature goes down to -, the first character
becomes “-” instead of a space, like “-05.5” [CR].
When no temperature data can be returned due to hardware
problems, the first character becomes “E” like”E00.0” [CR].
When several temperature sensors are equipped, Responses are
returned continuously.
“_31.5 _ _35.2 _ _33.4”[CR]
The first data is sensor 1, then one space, and the data of sensor
2 follows.
Unacceptable
“?”[CR]
Kommentare zu diesen Handbüchern