Sanyo DSR-3016 Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 96
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
BUILT-IN HARD DISK
Hard disk
Recording areas
The recording areas on the hard disk (normal recording area: 80%,
alarm recording area: 19%, archive area: 1%) are established
automatically when the power for the digital video recorder is turned
on. Images are recorded in the normal recording area when the
REC/STOP button is pressed, and they are recorded in the alarm
recording area when an alarm occurs. This is called the default
condition, and the following detailed settings can be confirmed in the
sections on RECORDING IMAGES IN THE NORMAL RECORDING
AREA and RECORDING IMAGES IN THE ALARM RECORDING
AREA (See page 22.) which are explained later. Furthermore,
settings such as the recording areas and picture quality can be
changed using the menu screens.
A Normal recording area
When the REC/STOP button is pressed while monitoring is in
progress, images are recorded in the normal recording area.
When start and end times are entered for each day of the week
and are then enabled, timer recording is automatically carried out
in the normal recording area between the times that have been set.
B Alarm recording area
ALARM REC MODE SET menu settings are required.
Alarm recording is enabled when ALARM RECORDING is set.
When a suspicious person is detected by the switch or motion
sensor that is connected to the alarm input terminal, an alarm is
recorded in the alarm recording area.
Pre-alarm recording is enabled when PRE-ALARM RECORDING
is set. Pre-alarm recording repeatedly records the same images as
for normal recording in the alarm recording area, and overwrites
these images after the set time interval, until an alarm is detected.
When pre-alarm recording is set, the image immediately before an
alarm occurred can be recorded.
C Archive area
This is the area for copying important images from the normal
recording area and the alarm recording area. The size of the archive
area can be set to a maximum of 10 GB (12.5% of total capacity when
using an 80-GB hard disk 6% of total capacity when using an 160-GB
hard disk) by changing the size of the normal recording area or the
alarm recording area.
Archive areaC
Normal recording areaNormal recording areaA
Alarm
recording
area
Alarm
recording
area
B
Hard disk recording areas
1%
1%
80%
80%
19%
19%
1%
80%
19%
Menu screen (initial setting)
This can be displayed by pressing the MENU button.
1
PICTURE QUALITY: NORMAL
Picture quality can be selected from five options.
(The recording speed changes in accordance with the picture
quality selected.)
2
AUDIO RECORDING: Can be set to ON or OFF.
3
REC RATE: Shows the recording interval and the
recording time.
Refer to the recording speed table for further details.
4
ALARM RECORDING: Can be set to ON or OFF.
When alarm recordings are to be made, select a setting such
as ENABLED for the OFF setting. The recording speed and
alarm duration will be displayed
A
Setting screen for normal recording area picture quality,
recording speed, etc.
B
Setting screen for alarm recording area picture quality,
recording speed, etc.
<RECORDING AREA SET>
TOTAL CAPACITY : 80GB
NORMAL RECORDING AREA : 80 %
AREA FULL RESET ->
ALARM RECORDING AREA : 19 %
AREA FULL RESET ->
ARCHIVE AREA : 1 %
AREA FULL RESET ->
CAUTION : WHEN THE AREA SETTING IS CHANGED,
THE WHOLE AREA WILL BE INITIALIZED !
A
B
A
B
C
<NORMAL REC MODE SET>
PICTURE QUALITY : NORMAL
AUDIO RECORDING : ON
REC RATE : 10FPS ( 57H)
REC CAMERA GROUP : OFF
1
3
2
<ALARM REC MODE SET>
PICTURE QUALITY : SUPER FINE
AUDIO RECORDING : ON
ALARM RECORDING : ENABLED
ALARM INTERLEAVE : ONLY
PROGRAM GROUP : OFF
REC RATE :@ 0.1FPS, DURATION: 40SEC
PRE-ALARM RECORDING : ON
REC RATE :@ **** FPS, DURATION: ***
=> (01010 ALARMS CAN BE RECORDED )
ALARM TRIGGER : ALARM
1
4
3
2
English
11
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 95 96

Kommentare zu diesen Handbüchern

Keine Kommentare